Part Number Hot Search : 
LNH13009 STK3082 DSP56321 T9G03009 150FC OP113ES 5ETTTS AD100
Product Description
Full Text Search
 

To Download 54MT140KPBF Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 54-94-104MT..KPbF Series
Vishay High Power Products
Three Phase AC Switch (Power Modules), 50 A to 100 A
FEATURES
* Package fully compatible with the industry standard INT-A-PAK power modules series * High thermal conductivity package, electrically insulated case
RoHS
COMPLIANT
* Outstanding number of power encapsulated components * Excellent power volume ratio * 4000 VRMS isolating voltage * UL E78996 approved
MTK
* Totally lead (Pb)-free * Designed and qualified for industrial level
PRODUCT SUMMARY
IO 50 A to 100 A
DESCRIPTION
A range of extremely compact, encapsulated three phase AC switches offering efficient and reliable operation. They are intended for use in general purpose and heavy duty applications as control motor starter.
MAJOR RATINGS AND CHARACTERISTICS
SYMBOL IO CHARACTERISTICS 54MT.K 50 TC 50 Hz IFSM 60 Hz 50 Hz 60 Hz I2t VRRM TStg, TJ Range Range 80 390 410 770 700 7700 94MT.K 90 80 950 1000 4525 4130 45250 800 to 1600 - 40 to 125 104MT.K 100 80 1130 A 1180 6380 5830 63800 A2s V C A2s UNITS A C
I2 t
Document Number: 94351 Revision: 05-May-08
For technical questions, contact: ind-modules@vishay.com
www.vishay.com 1
54-94-104MT..KPbF Series
Vishay High Power Products
ELECTRICAL SPECIFICATIONS VOLTAGE RATINGS
TYPE NUMBER VOLTAGE CODE 80 100 54MT..K 120 140 160 80 100 94/104MT..K 120 140 160 Note (1) For single AC switch VRRM, MAXIMUM REPETITIVE PEAK REVERSE VOLTAGE V 800 1000 1200 1400 1600 800 1000 1200 1400 1600 VRSM, MAXIMUM NON-REPETITIVE PEAK REVERSE VOLTAGE V 900 1100 1300 1500 1700 900 1100 1300 1500 1700 VDRM, MAXIMUM REPETITIVE PEAK OFF-STATE VOLTAGE, GATE OPEN CIRCUIT V 800 1000 1200 1400 1600 800 1000 1200 1400 1600 40 (1) 20 (1) IRRM/IDRM, MAXIMUM AT TJ = 125 C mA
Three Phase AC Switch (Power Modules), 50 A to 100 A
FORWARD CONDUCTION
PARAMETER Maximum IRMS output current at case temperature Maximum peak, one-cycle forward, non-repetitive on state surge current SYMBOL IO TEST CONDITIONS For all conduction angle t = 10 ms ITSM t = 8.3 ms t = 10 ms t = 8.3 ms t = 10 ms Maximum I2t for fusing I2t t = 8.3 ms t = 10 ms t = 8.3 ms Maximum I2t for fusing I2t VT(TO)1 VT(TO)2 rt1 rt2 VTM dI/dt IH IL No voltage reapplied 100 % VRRM reapplied No voltage reapplied 100 % VRRM reapplied 54MT.K 50 80 390 410 330 Initial TJ = TJ maximum 345 770 700 540 500 7700 1.16 1.44 12.54 11.00 2.68 94MT.K 90 80 950 1000 800 840 4525 4130 3200 2920 45 250 0.99 1.19 4.16 3.56 1.55 150 200 400 104MT.K 100 80 1130 1180 950 1000 6380 5830 4510 4120 63 800 0.99 V (I > x IT(AV)), TJ maximum 16.7 % x x IT(AV) < I < x IT(AV)), TJ maximum (I > x IT(AV)), TJ maximum Ipk = 150 A, TJ = 25 C tp = 400 s single junction TJ = 25 C, from 0.67 VDRM, ITM = x IT(AV), Ig = 500 mA, tr < 0.5 s, tp > 6 s TJ = 25 C, anode supply = 6 V, resistive load, grate open circuit TJ = 25 C, anode supply = 6 V, resistive load 1.15 3.90 m 3.48 1.53 V A/s A2s A2 s A UNITS A C
t = 0.1 to 10 ms, no voltage reapplied (16.7 % x x IT(AV) < I < x IT(AV)), TJ maximum
Low level value of threshold voltage High level value of threshold voltage Low level value on-state slope resistance High level value on-state slope resistance Maximum on-state voltage drop Maximum non-repetitve rate of rise of turned on current Maximum holding current Maximum latching current
mA
www.vishay.com 2
For technical questions, contact: ind-modules@vishay.com
Document Number: 94351 Revision: 05-May-08
54-94-104MT..KPbF Series
Three Phase AC Switch Vishay High Power Products (Power Modules), 50 A to 100 A
BLOCKING
PARAMETER RMS isolation voltage Maximum critical rate of rise of off-state voltage SYMBOL VINS dV/dt (1) TEST CONDITIONS TJ = 25 C all terminal shorted f = 50 Hz, t = 1 s TJ = TJ maximum, linear to 0.67 VDRM, gate open circuit 54MT.K 94MT.K 4000 500 104MT.K UNITS V V/s
Note (1) Available with dV/dt = 1000 V/s, to complete code add S90 i. e. 104MT160KBS90
TRIGGERING
PARAMETER Maximum peak gate power Maximum average gate power Maximum peak gate current Maximum peak negative gate voltage Maximum required DC gate voltage to trigger SYMBOL PGM PG(AV) IGM - VGT TJ = - 40 C VGT TJ = 25 C TJ = 125 C TJ = - 40 C Maximum required DC gate current to trigger Maximum gate voltage that will not trigger Maximum gate current that will not trigger IGT TJ = 25 C TJ = 125 C VGD TJ = TJ maximum, rated VDRM applied IGD 6 mA Anode supply = 6 V, resistive load TJ = TJ maximum TEST CONDITIONS 54MT.K 94MT.K 10 2.5 2.5 10 4.0 2.5 1.7 270 150 80 0.25 V mA V 104MT.K UNITS W A
THERMAL AND MECHANICAL SPECIFICATIONS
PARAMETER Maximum junction operating and storage temperature range SYMBOL TJ, TStg DC operation per single AC switch Maximum thermal resistance, junction to case RthJC DC operation per junction 180 C sine cond. angle per single AC switch 180 C sine cond. angle per junction Maximum thermal resistance, case to heatsink Mounting torque 100 % Approximate weight to heatsink to terminal RthCS Per module Mounting surface smooth, flat and grased A mounting compound is recommended and the torque should be rechecked after a period of 3 hours to allow for the spread of the compound. Lubricated threads. 0.52 1.05 0.56 1.12 TEST CONDITIONS 54MT.K 94MT.K - 40 to 125 0.39 0.77 0.40 0.80 0.03 4 to 6 3 to 4 225 Nm g 0.34 0.69 0.36 0.72 K/W 104MT.K UNITS C
Document Number: 94351 Revision: 05-May-08
For technical questions, contact: ind-modules@vishay.com
www.vishay.com 3
54-94-104MT..KPbF Series
Vishay High Power Products
Three Phase AC Switch (Power Modules), 50 A to 100 A
R CONDUCTION PER JUNCTION
DEVICES 180 54MT.K 94MT.K 104MT.K 0.072 0.033 0.027 SINUSOIDAL CONDUCTION AT TJ MAXIMUM 120 0.085 0.039 0.033 90 0.108 0.051 0.042 60 0.152 0.069 0.057 30 0.233 0.099 0.081 180 0.055 0.027 0.023 RECTANGULAR CONDUCTION AT TJ MAXIMUM 120 0.091 0.044 0.037 90 0.117 0.055 0.046 60 0.157 0.071 0.059 30 0.236 0.100 0.082 K/W UNITS
Note * Table shows the increment of thermal resistance RthJC when devices operate at different conduction angles than DC
Maximum Allowable Case Temperature (C)
120 110 100 90 80
54MT..K Series Device fully turned-on
Instantaneous On-State Current (A)
130
1000
TJ = 25 C TJ = 125 C
100
Per single AC switch ~ IRMS
10
70
54MT..K Series Per junction
1
For all conduction angles
60
0
10
20
30
40
50
60
0
1
2
3
4
5
6
RMS Output Current (A)
Fig. 1 - Current Ratings Characteristic
Instantaneous On-State Voltage (V)
Fig. 2 - Forward Voltage Drop Characteristics
350
350
Maximum Total Power Loss (W) (Per Total Module)
Maximum Total Power Loss (W) (Per Total Module)
300 250
54MT..K Series TJ = 125 C Device fully turned-on
180 120 90 60 30
0.
300 250 200 150 100 50 0
1
R th
0.2
K/
W
SA
=
0.3
K/
0.
W
05 W K/
K/
W
-
O
150
Conduction angle
100 50 0
0
10
RMS Output Current (A)
Fig. 3 Total Power Loss Characteristics
www.vishay.com 4
O
200
R
K/W 0.7 K /W 1.0 K /W
0.5
2.0 K/W
20
30
40
50
60
0
25
50
75
100
125
Maximum Allowable Ambient Temperature (C)
For technical questions, contact: ind-modules@vishay.com
Document Number: 94351 Revision: 05-May-08
54-94-104MT..KPbF Series
Three Phase AC Switch Vishay High Power Products (Power Modules), 50 A to 100 A
350 325
300 275 250 225 200 175 150
Maximum Allowable Case Temperature (C)
Peak Half Sine Wave On-State Current (A)
At any rated load condition and with rated VRRM applied following surge. Initial TJ = 125 C at 60 Hz 0.0083 s at 50 Hz 0.0100 s
130 120 110 100 90 80 70 60
94MT..K Series Device fully turned-on
Per single AC switch IRMS ~
54MT..K Series Per junction 1 10 100
For all conduction angles
50
0
20
40
60
80
100
120
Number of Equal Amplitude Half Cycle Current Pulses (N) Fig. 4 - Maximum Non-Repetitive Surge Current
RMS Output Current (A)
Fig. 6 - Current Ratings Characteristic
Peak Half Sine Wave On-State Current (A)
350
Maximum non-repetitive surge current versus pulse train duration. Control of conduction may not be maintained. Initial TJ = 125 C No voltage reapplied Rated VRRM reapplied
Instantaneous On-State Current (A)
400
1000
100
300
250
TJ = 25 C
10
TJ = 125 C 94MT..K Series Per junction
200
54MT..K Series Per junction
150
1
0.01
0.1
1
0
1
2
3
4
5
Pulse Train Duration (s)
Fig. 5 - Maximum Non-Repetitive Surge Current
Instantaneous On-State Voltage (V)
Fig. 7 - Forward Voltage Drop Characteristics
450
450
Maximum Total Power Loss (W) (Per Total Module)
Maximum Total Power Loss (W) (Per Total Module)
400 350 300
94MT..K Series TJ = 125 C Device fully turned-on
R th
400 350 300 250 200 150 100 50 0
0. 05
SA
O
200 150 100 50 0
Conduction angle
0
10
20
RMS Output Current (A)
Fig. 8 - Total Power Loss Characteristics
Document Number: 94351 Revision: 05-May-08
O
250
180 120 90 60 30
0.
15
=
K/
03 0.
K/ W
W
K/ W
0.3
-
K/W
R
0.5 K/W 0.7 K /W 1.0 K /W
1.5 K/W
0 25 50 75 100 125
30
40
50
60
70
80
90 100
Maximum Allowable Ambient Temperature (C)
For technical questions, contact: ind-modules@vishay.com
www.vishay.com 5
54-94-104MT..KPbF Series
Vishay High Power Products
750 700
Three Phase AC Switch (Power Modules), 50 A to 100 A
130
650 600 550 500 450 400 350
Maximum Allowable Case Temperature (C)
Peak Half Sine Wave On-State Current (A)
At any rated load condition and with rated VRRM applied following surge. Initial TJ = 125 C at 60 Hz 0.0083 s at 50 Hz 0.0100 s
120 110 100 90 80 70
104MT..K Series Device fully turned-on
Per single AC switch IRMS ~
94MT..K Series Per junction 1 10 100
For all conduction angles
60
0
20
40
60
80
100
120
Number of Equal Amplitude Half Cycle Current Pulses (N) Fig. 9 - Maximum Non-Repetitive Surge Current
RMS Output Current (A)
Fig. 11 - Current Ratings Characteristic
900
Peak Half Sine Wave On-State Current (A)
800 700 600 500 400 300
Maximum non-repetitive surge current versus pulse train duration. Control of conduction may not be maintained. Initial TJ = 125 C No voltage reapplied Rated VRRM reapplied
Instantaneous On-State Current (A)
1000
1000
100
TJ = 25 C
10
TJ = 125 C 104MT..K Series Per junction
94MT..K Series Per junction 0.01 0.1 1
1
0
1
2
3
4
5
Pulse Train Duration (s)
Fig. 10 - Maximum Non-Repetitive Surge Current
Instantaneous On-State Voltage (V)
Fig. 12 - Forward Voltage Drop Characteristics
500
500
Maximum Total Power Loss (W) (Per Total Module)
450 400 350 300 250 200 150 100 50 0
180 120 90 60 30
Maximum Total Power Loss (W) (Per Total Module)
104MT..K Series TJ = 125 C Device fully turned-on
450
R th
SA
0 0.
400 350 300 250 200 150 100 50 0
0.
5
15
=
W K/
0.
K/
03
W
K/ W
O
0.3
0.5
-
Conduction angle
0
20
RMS Output Current (A)
Fig. 13 - Total Power Loss Characteristics
www.vishay.com 6
O
K/W
R
K/W 0.7 K /W 1.0 K /W
1.5 K/W
0 25 50 75 100 125
40
60
80
100
120
Maximum Allowable Ambient Temperature (C)
For technical questions, contact: ind-modules@vishay.com
Document Number: 94351 Revision: 05-May-08
54-94-104MT..KPbF Series
Three Phase AC Switch Vishay High Power Products (Power Modules), 50 A to 100 A
1100 1000
Peak Half Sine Wave On-State Current (A)
Peak Half Sine Wave On-State Current (A)
900 800 700 600 500 400
At any rated load condition and with rated VRRM applied following surge. Initial TJ = 125 C at 60 Hz 0.0083 s at 50 Hz 0.0100 s
1200 1100 1000 900 800 700 600 500 400
Maximum non-repetitive surge current versus pulse train duration. Control of conduction may not be maintained. Initial TJ = 125 C No voltage reapplied Rated VRRM reapplied
104MT..K Series Per junction 1 10 100
104MT..K Series Per junction 0.01 0.1 1
Number of Equal Amplitude Half Cycle Current Pulses (N) Fig. 14 - Maximum Non-Repetitive Surge Current
Pulse Train Duration (s)
Fig. 15 - Maximum Non-Repetitive Surge Current
10 Steady state value
ZthJC - Transient Thermal Impedance (C/W)
RthJC = 1.05 K/W 1 RthJC = 0.77 K/W RthJC = 0.69 K/W (DC operation) 94MT..K Series
54MT..K Series
104MT..K Series 0.1
0.01 Per junction
0.001 0.001
0.01
0.1
1
10
Square Wave Pulse Duration (s)
Fig. 16 - Thermal Impedance ZthJC Characteristics
100
Instantaneous Gate Voltage (V)
10
Rectangular gate pulse a) Recommended load line for rated dI/dt: 20 V, 30 tr = 0.5 s, tp 6 s b) Recommended load line for 30 % rated dI/dt: 20 V, 65 tr = 1 s, tp 6 s TJ = 125 C
(1) PGM = 100 W, tp = 500 s (2) PGM = 50 W, tp = 1 ms (3) PGM = 20 W, tp = 25 ms (4) PGM = 10 W, tp = 5 ms (a) (b) TJ = 25 C TJ = -40 C
1 VGD IGD 0.1 0.001 0.01
(4)
(3)
(2)
(1)
54/ 94/ 104MT..K Series 0.1 1
Frequency limited by PG(AV) 10 100 1000
Instantaneous Gate Current (A)
Fig. 17 - Gate Characteristics
Document Number: 94351 Revision: 05-May-08
For technical questions, contact: ind-modules@vishay.com
www.vishay.com 7
54-94-104MT..KPbF Series
Vishay High Power Products
Three Phase AC Switch (Power Modules), 50 A to 100 A
ORDERING INFORMATION TABLE
Device code
10
1 1 -
4
2
MT
3
160
4
K
PbF
5
Current rating code: 5 = 50 A (average) 9 = 90 A (average) 10 = 100 A (average) AC switch Essential part number Voltage code x 10 = VRRM (see Voltage Ratings table) PbF = Lead (Pb)-free
2 3 4 5
-
Note * To order the optional hardware go to www.vishay.com/doc?95172
CIRCUIT CONFIGURATION
A 1 3
B 5
C
2 D
4 E
6 F
LINKS TO RELATED DOCUMENTS Dimensions http://www.vishay.com/doc?95004
www.vishay.com 8
For technical questions, contact: ind-modules@vishay.com
Document Number: 94351 Revision: 05-May-08
Legal Disclaimer Notice
Vishay
Disclaimer
All product specifications and data are subject to change without notice. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, "Vishay"), disclaim any and all liability for any errors, inaccuracies or incompleteness contained herein or in any other disclosure relating to any product. Vishay disclaims any and all liability arising out of the use or application of any product described herein or of any information provided herein to the maximum extent permitted by law. The product specifications do not expand or otherwise modify Vishay's terms and conditions of purchase, including but not limited to the warranty expressed therein, which apply to these products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications unless otherwise expressly indicated. Customers using or selling Vishay products not expressly indicated for use in such applications do so entirely at their own risk and agree to fully indemnify Vishay for any damages arising or resulting from such use or sale. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. Product names and markings noted herein may be trademarks of their respective owners.
Document Number: 91000 Revision: 18-Jul-08
www.vishay.com 1


▲Up To Search▲   

 
Price & Availability of 54MT140KPBF

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X